Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Region preferences
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
EC HPLC column (analytical), NUCLEODUR PFAS, 3 µm, 50x2 mm

$875.00 * $0.00 * (0% Saved)
*taxes and shipping not included
Delivery time approx. 5 working days
Item number: 760663.20 024020274045
Package unit 1 Column(s) Do you have any questions?
Please contact us. Hydrophobic reversed phase with distinct polar selectivity for special PFAS analysis.... more
Hydrophobic reversed phase with distinct polar selectivity for special PFAS analysis. Suitability for PFAS analysis is assured through qualified batch analysis. This HPLC phase is made of high purity NUCLEODUR HPLC silica gel and is extensively endcapped. Due to a low bleeding characteristics these columns are suitable for high sensitivity LC/MS analysis.
Method | HPLC, analytical |
Brand | NUCLEODUR |
Base material | NUCLEODUR - high purity silica |
Phase | NUCLEODUR PFAS |
USP listing | Not available or proprietary |
Surface chemistry | Proprietary |
Mode | Reversed phase (RP) |
Type | EC HPLC column (analytical) |
Hardware | Stainless steel |
Column length | 50 mm |
Column inner diameter | 2 mm |
Particle type | Fully porous particle (FPP) |
Particle shape | Spherical |
Particle size | 3 µm |
Eluent in HPLC column | Acetonitrile – water |
Recommended application(s) | PFAS |
Endcapped | Yes |
Carbon content | Not available or proprietary |
pH stability | 1.0–9.0 |
Pore size | 110 Å |
Specific surface according to BET | 340 m²/g |
Temperature stability (max) | 60 °C |
Tmax (phosphate buffer) | 40 °C |
Pressure stability (max) | 600 bar |
Column volume | 0.15 mL |
Storage temperature | 15–25 °C |
Scope of delivery | 1x analytical HPLC column, instruction leaflet, certificate of analysis + batch document |
Hazardous material | No |
- Download Instructions NUCLEODUR PFAS HPLC columns (DE/EN)
- Download Application Note: PFAS analysis according to EPA 8327 (EN)
- Download Application Note - PFAS analysis according to ISO 21675:2019, DIN 38407-42 (EN)
- Download Application Note: PFAS HPLC analysis according to EPA 533 and 537.1(EN)
- Download Application Note: PFAS analysis according to EPA 533 (EN)
- Download Application Note: PFAS analysis according to EPA 537.1 (EN)
- Download Brochure NUCLEODUR and NUCLEOSHELL modern HPLC phases (EN)
Content 1 Column(s)
REF 760673.20
$