Tube test NANOCOLOR ortho-Phosphate 15 Robot
Price on request
*taxes and shipping not included
Tube test for the determination of ortho- and total Phosphate. Suitable for automated water analysis on the Skalar Robot SP2000series. Precise rapid tests for all kind of water and waste water samples.
| Application | drinking water, groundwater, surface water, wastewater |
|---|---|
| Based on norm | Analogous to EPA 365.2+3, APHA 4500-P E, DIN EN ISO 6878 – D11 |
| Brand | NANOCOLOR |
| Crack-Set | No |
| Evaluable on | VIS, VIS II |
| Gross weight (incl. packaging) | 456.6 g / 1.01 lbs |
| Hazardous material | Yes |
| Measuring range | Phosphate (ortho) - 0.30–15.00 mg/L P , Phosphate (ortho) - 1.0–45.0 mg/L PO₄³⁻ |
| Method | Phosphate - Phosphomolybdenum blue |
| NanOx Metal | No |
| NanOx N | No |
| Packaging dimensions | 160 x 110 x 119 mm / 6.30 x 4.33 x 4.69 Inch |
| Parameter | Phosphate (ortho) |
| Platform | NANOCOLOR tube tests |
| Remark | Measuring range on NANOCOLOR VIS II |
| Scope of delivery | Rugged box with 20 test tubes. Sufficient for 20 tests. |
| Sea water analysis | Yes |
| Shelf life (from production) | 1 Year(s) |
| Sludge reagent set | No |
| Storage temperature | 15–25 °C / 59–77 °F |
| Test method | Photometric |
| Test No. | 0-57 |
| Test range | Medium |
SPE Multi 96‑well plates in robot systems for reproducible results
CHROMABOND MULTI 96-well plates provide a high-throughput solution for sample preparation by processing 96 samples in a standard 8 x 12 microcolumn plate format compatible with standard 96-well plate liquid handling technologies and injection systems. The 96-well PP microcolumn plates are supplied with PE filter elements and a cavity volume of 1.5 mL. Different adsorbent weights 10, 25, 50 and 100 mg supplied with any CHROMABOND SPE adsorbents for simultaneous preparation of 96 samples. An easy method transfer from CHROMABOND columns or CHROMAFIX cartridges to CHROMABOND 96-well plates is possible.
Advantages of this high-throughput system
- Simultaneous preparation of 96 samples
- Economical by saving time and solvent
- Use of multi-channel pipettors facilitates liquid transfer steps
- Readily adaptable to all common automated/robotic handling systems
- Minimized dead volume (≤ 40 µL)
Instrument compatibility
CHROMABOND MULTI 96 SPE plates are compatible with, e.g., the following liquid handling and / or SPE automation systems:
- Perkin Elmer MultiProbe II MultiProbe II
- Tomtec Quadra 3 and Quadra 3 SPE
- Hamilton Microlab SPE Workstation
- Beckman Schar Biomek 2000
- Messschieber Life Science RapidTrace
- Gilson ASPEC XL4 and ASPEC XL and Gilson 215 SPE Liquid Handler
- Tecan Genesis FE500
- Eppendorf epMotion