Zum Hauptinhalt springen Zur Suche springen Zur Hauptnavigation springen

MN Bead Tube Type C

Yeast and fungi are complex sample materials and therefore often require mechanical homogenization to ensure thorough lysis. The MN Bead Tubes Type C (containing 1-3 mm corundum) are recommended for fast and efficient homogenization of yeast and fungal samples.

Yeast, fungi

Type C (corundum) 1 - 3 mm corundum

Compatible with the following kits

Scalable options

Solutions for small sample amounts

MN Bead Tubes Type C, 2 ml tubes

  • 2 ml screw cap tubes
  • Prefilled with 1-3 mm corundum beads
  • compatible with common bead beating devices
  • click here for more information

Bulk solutions for different sample amounts

MN Beads Type C Bulk (DNA and nuclease free)

  • bulk beads
  • DNA and nuclease free
  • 1-3 mm corundum beads
  • compatible with common bead beating devices
  • click here for more information

Sample processing recommendations

In order to obtain optimal yields of DNA from sample material, a complete disruption of the sample material is necessary. Sample disruption efficiency depends on the parameters such as type of bead tube or bead plate, time and frequency and also the disruption device. Please find below our suggested recommendations for the MN Bead Tubes Type C in combination with different nucleic acid purification kits.

MN Bead Tube Holder in combination with a Vortex-Genie 2

Sample disruption using the MN Bead Tube Holder is a very straight forward and easy method to homogenize your sample. The MN Bead Tube Holder is available for 2 ml and 5 ml bead tubes.

Sample type
Processing time
Buffer and volume
Recommended kit
Yeast samples Approx. 10 - 20 min full speed, RT according to the standard protocolNucleoSpin DNA Yeast
Yeast samples Approx. 10 - 20 min full speed, RTaccording to the standard protocolNucleoSpin Microbial DNA

Sample processing recommendation using a RETSCH Mixer Mill

An alternative in sample disruption of biological materials are bead beating mills. MN Bead Tubes (with the exception of MN Bead Tubes Type F) can be combined with most disruption devices. Please find below the recommendation for MN Bead Tubes Type C incombination with different purification kits and the RETSCH Mixer Mill. Click here to find our latest Application Note for MN Bead Tubes and the Retsch Mixer Mill.

MN Bead Tubes Type C


Sample type
Processing time
Buffer and volume (supplementary)
Bead Tube
Recommended kit
Yeast (Saccharomyces cerevisiae) 5 min, 30 Hz, RT according to the standard protocol MN Bead Tubes Type C NucleoSpin DNA Yeast
Yeast (Saccharomyces cerevisiae) 12 min, 30 Hz, RT <40 mg microbial pellet + 100 µl BE + 40 µL MG + 10 µl Proteinase K MN Bead Tubes Type C NucleoSpin Microbial DNA
Filamentous fungi (Aspergillus sepc. 12 min, 30 Hz, RT <40 mg microbial pellet + 100 µl BE + 40 µL MG + 10 µl Proteinase K
MN Bead Tubes Type C NucleoSpin Microbial DNA
Rhizopus spec. 12 min, 30 Hz, RT <40 mg microbial pellet + 100 µl BE + 40 µL MG + 10 µl Proteinase K MN Bead Tubes Type C NucleoSpin Microbial DNA