Login
   

PCB from sludge

Method:
Matrix
Application-No.:
SPE
soil, sludge
301400




Substances:
PCB-28; PCB-52; PCB-101; PCB-138; PCB-153; PCB-180; PCB-209
Column:
CHROMABOND® NAN, 6 mL,  700/2000/700 mg
Phase:
CHROMABOND® NAN
REF number:
730149



Sample pretreatment:
Extract 2 g lyophilized sludge with 70 mL n-hexane, evaporate extract and
finally fill to 10 mL with n-hexane



Conditions:
Column conditioning:
10 mL n-hexane

Sample application:
Aspirate 2 mL of the extract into the column

Elution:
Aspirate 40 mL n-hexane slowly through the column with weak vacuum, then
evaporate and fill to 5 mL with n-hexane




Subsequent analysis:
For further analysis we recommend GC
e.g., GC Appl. No. 211180 with capillary column OPTIMA® 5 MS,  50 m, 0.20 mm, 0.20 µm (REF 726210.50)



Author(-s):
SPE department
Source:
MACHEREY-NAGEL



Keywords:
PCBs; sludge; soil






Recovery rates:

PCB-28:    104 %
PCB-52:    100 %
PCB-101:    99 %
PCB-138:    98 %
PCB-153:  101 %
PCB-180:    98 %
PCB-209:  104 %











www.mn-net.com
Concerning questions to literature applications please contact the cited author/s. Chemicals mentioned in applications are not manufactured or sold by MACHEREY-NAGEL. Applications mentioned in MACHEREY-NAGEL literature or databases are provided for informational purposes only. MACHEREY-NAGEL does not warrant that all applications have been tested in MACHEREY-NAGEL laboratories using MACHEREY-NAGEL products.