Login
   

Rapid Determination of Heavy Polycyclic Aromatic Hydrocarbons in Edible Fats and Oils

Method:
Matrix
Application-No.:
SPE
edible oil, fat
303060




Substances:
6-nuclear PAHs; 5-nuclear PAHs; 4-nuclear PAHs; 3-nuclear PAHs; 2-nuclear PAHs; benzo[a]anthracene; benzo[b]chrysene
Column:
CHROMABOND® HR-P, 6 mL, 500 mg (glass columns)
Phase:
CHROMABOND® HR-P
REF number:
730111G



Sample pretreatment:
In a small beaker 2.0 - 2.5 g of sample were dissolved in 5 mL isohexane / t-butyldimethylether (95:5, v/v). 50 μL internal standard solution (benzo[b]chrysene,
1 ng/μL isooctane) were added.



Conditions:
Column conditioning: with 10 mL isohexane / t-butyldimethylether (95:5, v/v)

Sample application: The solution was transferred onto the cartridge and the beaker rinsed with additional 2 mL isohexane / t-butyldimethylether (95:5, v/v).

Column washing: The cartridge was washed with 10 mL isohexane / t-butylmethylether (95:5, v/v), followed by a small volume of air (about 3 mL). The eluate was discarded afterwards. The cartridges was washed again with 10 mL isohexane / t-buthylmethylether (80:20, v/v), followed by a small volume of air (about 3 mL), the eluate discarded once more. Again the cartridges was washed with 10 mL isohexane / t-buthylmethylether (50:50, v/v) followed by a small volume of air (about 3 mL), the eluate once more discarded.

Elution: PAHs were eluted with 20 mL THF.

Evaporation: 50 μL acetonitrile / diethylenglycole (2:1, v/v) were added and the eluate evaporated to dryness. The residue was dissolved in 500 μL acetonitrile and transferred to an autosampler vial.



Subsequent analysis:
HPLC, e.g with NUCLEODUR® C18 PAH



Author(-s):
Weißhaar, R.
Source:
Eur. J. Lipid Sci. Technol. 104 (2002) 282-285



Keywords:
PAHs; fat; oil






Recovery rates:

Benzo(b)chrysene           -   85-95 %
Benzo(a)anthracene        -   70-75 %
6- and 5-nuclear PAHs     -   85-95  %
4-nuclear PAHs                -   60-75%
2- and 3-nuclear PAHs     -      <75 %











www.mn-net.com
Concerning questions to literature applications please contact the cited author/s. Chemicals mentioned in applications are not manufactured or sold by MACHEREY-NAGEL. Applications mentioned in MACHEREY-NAGEL literature or databases are provided for informational purposes only. MACHEREY-NAGEL does not warrant that all applications have been tested in MACHEREY-NAGEL laboratories using MACHEREY-NAGEL products.
MACHEREY-NAGEL does not warrant the correctness of the applications.


 Print   
     
  