Login
     
  
   
CHROMABOND® Diamino
CHROMABOND® QuEChERS
Special silica phase for determination of pesticides in food samples
Features
Base material silica, pore size 60 Å, particle size 45 μm, specific surface 500 m2/g, pH stability 2–8
Primary and Secondary Amine functions (PSA), 5 % C
Removes polar compounds (e.g., organic acids, pigments, sugars) from matrices like fruit or vegetables
Similar phases: Supelclean PSA, Bond Elut PSA
Recommended application:
special SPE phase for quick and cheap determination of pesticides in strongly matrix-contaminated samples by GC-MS and LC-MS (see application 303770 and application 305060)
QuEChERS method = Quick Easy Cheap Effective Rugged Safe


QuEChERS method and pre-mixes
Within a few years after its development by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food samples by GC-MS or LC-MS, allowing rapid and cheap clean-up of strongly matrix-contaminated samples.
For optimizing the extraction of pH-dependent compounds, for minimizing decomposition of sensitive substances, and for broadening the matrix spectrum, different modifications of the QuEChERS method have been elaborated.
In addition to the required adsorbent CHROMABOND® Diamino MACHEREY-NAGEL offers a number of individually weighed and premixed buffer and extraction mixtures, specially composed for different sample matrices.
  For extraction,  the European standard EN 15662 recommends a citrate extraction mix (Mix I), while AOAC standard 2007.1 uses an acetate extraction mix (Mix II).
For clean-up, the Diamino phase (PSA) removes, e.g., sugars and organic acids. Magnesium sulfate removes water, C18 ec removes nonpolar interferences such as fats and the Carbon phase removes pigments, sterols, and nonpolar interferences.
For selection of the proper clean-up mix see table below.

For more information please see our Chroma-News or visit the original references at www.quechers.com.


QuEChERS mixes
Sample property
Low fat content
(e.g., apples, strawberries)
Moderate content of chlorophyll and carotinoids (e.g., carrots, lettuce) Higher content of chlorophyll and carotinoids (e.g., bell peppers, spinach) Higher fat content
(e.g., avocado)
CHROMABOND® QuEChERS extraction mixes
Citrate or acetate extraction Citrate or acetate extraction Citrate extraction Citrate extraction
Mix I or Mix II Mix I or Mix II Mix I Mix I
CHROMABOND® QuEChERS clean-up mixes
Diamino clean-up Diamino/Carbon clean-up Diamino/Carbon clean-up
(higher Carbon content)
Diamino/C18 ec clean-up
Mix III Mix IV Mix V Mix VI


Ordering information
    Volume Description Composition REF Pack of
  CHROMABOND® QuEChERS extraction buffer mixes
  15 mL* Mix I citrate extraction mix 4 g MgSO4, 1 g NaCl,
0.5 g Na2H citrate ∙ 1.5 H2O,
1 g Na3 citrate ∙ 2 H2O
730970 50
  15 mL* Mix II acetate extraction mix 6 g MgSO4, 1.5 g Na acetate 730971 50
  CHROMABOND® QuEChERS clean-up mixes
  15 mL* Mix III Diamino clean-up mix 0.15 g CHROMABOND®
Diamino with 0.9 g MgSO4
730972 50
  15 mL* Mix IV Diamino/Carbon
clean-up mix
0.15 g CHROMABOND®
Diamino with 0.9 g MgSO4
and 15 mg Carbon
730973 50
  15 mL* Mix V Diamino/Carbon
clean-up mix
0.15 g CHROMABOND®
Diamino with 0.9 g MgSO4
and 45 mg Carbon
730975 50
  15 mL* Mix VI Diamino/C18 ec
clean-up mix
0.15 g CHROMABOND®
Diamino with 0.9 g MgSO4
and 150 mg C18 ec
730974 50
  CHROMABOND® Diamino polypropylene columns
  3 mL   adsorbent weight 200 mg   730561 50
  6 mL   adsorbent weight 500 mg   730562 30
  CHROMABOND® Diamino adsorbent
          730653.20 20 g
          730653 100 g
    CHROMABOND® QuEChERS accessories
    50 mL polypropylene centrifuge tube with screw cap 730223 50
* 15 mL centrifuge tubes with screw cap (2 mL or 50 mL centrifuge tubes on request)
A number of custom-made QuEChERS mixes is available on request.