Login
     
  
     
Instruction leaflet:
NUCLEOSIL®
RP columns


  
   
NUCLEOSIL® standard C8 phases    
Octyl modified silica phases for HPLC
C8 ec: medium density modification, endcapped · 9 % C · USP L7
C8: not encapped · USP L7
Features
Nonpolar phases for RP chromatography
NUCLEOSIL® C8 ec:
Endcapped, available pore sizes 50 and 100 Å, particle size 5 µm
Separation mechanism based on hydrophobic (van der Waals) interactions, slight residual silanol interactions
Corresponding NUCLEODUR® phase: see NUCLEODUR® C8 ec
NUCLEOSIL® C8:
Not endcapped, available pore sizes 100, 120, 300 and 500 Å,
available particle sizes 3 µm, 5 µm, 7 µm and 10 µm
Separation mechanism based on hydrophobic (van der Waals) interactions, noticeable silanol interactions
pH stability at 20 °C for both types: 2–8; carbon content depends on phase (see tables)
  For applications click here.
Standard NUCLEOSIL® C8 phases are available as:
Packed EC columns for analytical HPLC
Bulk packings

 Print   
     
EC standard columns for analytical HPLC
Ordering information
Eluent in column acetonitrile – water
Length 125 mm 150 mm 250 mm   EC guard columns* CC guard columns**
NUCLEOSIL® 50-5 C8 ec · 5 µm particles · 50 Å pores · 9 % C · endcapped    
4.6 mm ID     720092.46   721097.30 721834.40
NUCLEOSIL® 100-5 C8 ec · 5 µm particles · 100 Å pores · 9 % C · endcapped    
4 mm ID     720165.40   721096.30 721805.40
4.6 mm ID     720165.46   721096.30 721805.40
NUCLEOSIL® 100-5 C8 · 5 µm particles · 100 Å pores · 8,5 % C · not endcapped    
4 mm ID 720001.40   720013.40   721194.30 721601.40
4.6 mm ID 720001.46 720990.46 720013.46   721194.30 721601.40
NUCLEOSIL® 100-7 C8 · 7 µm particles · 100 Å pores · 8,5 % C · not endcapped    
4 mm ID     720017.40      
4.6 mm ID     720017.46      
NUCLEOSIL® 100-10 C8 · 10 µm particles · 100 Å pores · 8,5 % C · not endcapped    
4 mm ID     720022.40      
4.6 mm ID      720022.46      
NUCLEOSIL® 120-3 C8 · 3 µm particles · 120 Å pores · 6,5 % C · not endcapped    
4 mm ID 720071.40       721093.30 721785.40
4.6 mm ID 720071.46 720214.46     721093.30 721785.40
NUCLEOSIL® 120-5 C8 · 5 µm particles · 120 Å pores · 6,5 % C · not endcapped    
4 mm ID 720050.40   720052.40   721095.30 721787.40
4.6 mm ID 720050.46 720735.46 720052.46   721095.30 721787.40
NUCLEOSIL® 300-5 C8 · 5 µm particles · 300 Å pores · ~ 3 % C · not endcapped    
4.6 mm ID     720062.46   721061.30 721101.40
Columns/pack 1 1 1   3 3
* EC 4/3 guard column cartridges are used for EC columns of 4 and 4.6 mm ID with the Column Protection System guard column holder (REF 718966).
** CC 8/4 guard column cartridges are used for EC columns of 4 and 4.6 mm ID with guard column adapter EC (REF 721359).
Custom-packed EC columns with other dimensions are available on request.

 Print   
     
NUCLEOSIL® C8 bulk packings

Ordering information
Phase Endcapped Carbon content Pore size Particle size Pack of 10 g Pack of 100 g
NUCLEOSIL 50-5 C8 ec yes 9 % 50 Å 5 µm 712032.10 712032.100
NUCLEOSIL 100-5 C8 ec yes 9 % 100 Å 5 µm 712101.10 712101.100
NUCLEOSIL 100-5 C8 no 8.5 % 100 Å 5 µm 712100.10 712100.100
NUCLEOSIL 100-7 C8 no 8.5 % 100 Å 7 µm 712110.10 712110.100
NUCLEOSIL 100-10 C8 no 8.5 % 100 Å 10 µm 712120.10 712120.100
NUCLEOSIL 120-3 C8 no 6.5 % 120 Å 3 µm 712570.10 712570.100
NUCLEOSIL 120-5 C8 no 6.5 % 120 Å 5 µm 712580.10 712580.100
NUCLEOSIL 120-7 C8 no 6.5 % 120 Å 7 µm 712500.10 712500.100
NUCLEOSIL 120-10 C8 no 6.5 % 120 Å 10 µm 712590.10 712590.100
NUCLEOSIL 300-5 C8 no ~ 3 % 300 Å 5 µm 712650.10 712650.100
NUCLEOSIL 300-7 C8 no ~ 3 % 300 Å 7 µm 712550.10 712550.100
NUCLEOSIL 300-10 C8 no ~ 3 % 300 Å 10 µm 712660.10 712660.100
NUCLEOSIL 500-7 C8 no < 1 % 500 Å 7 µm 712830.10 712830.100
 

 Print   
   
  