OPTIMA® 5
Capillary columns for GC
Features
5 % phenyl – 95 % methylpolysiloxane · USP G27, G36
Nonpolar standard phase with large range of application
For numerous applications click here.
Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed columns see OPTIMA® 5 MS Accent
Similar phases: SE-54, SE-52, HP-5, SPB-5, CP‑Sil 8, Rtx‑5, 007-5, BP5, MDN‑5, AT‑5, ZB‑5
Columns with 0.1–0.32 mm ID and films < 3 μm: max. temperature for isothermal operation 340 °C, max. temperature for short isotherms in a temperature program 360 °C;
0.53 mm ID columns with films < 3 μm: max. temperatures 320 and 340 °C, resp.
thick film columns with films > 3 μm: max. temperatures 300 and 320 °C, resp.


Ordering information
Film [μm] 10 m   15 m   25 m 30 m 50 m 60 m  
0.1 mm ID (0.4 mm OD)
0.10 726846.10                
0.2 mm ID (0.4 mm OD)
0.10         726854.25        
0.20         726857.25   726857.50    
0.35         726860.25   726860.50    
0.50         726863.25   726863.50    
0.25 mm ID (0.4 mm OD)
0.10         726911.25 726911.30 726911.50 726911.60  
0.25 726056.10   726056.15   726056.25 726056.30 726056.50 726056.60  
0.35         726623.25 726623.30 726623.50 726623.60  
0.50         726099.25 726099.30 726099.50 726099.60  
1.00         726807.25 726807.30 726807.50 726807.60  
0.32 mm ID (0.5 mm OD)
0.10 726313.10   726313.15   726313.25 726313.30 726313.50 726313.60  
0.25     726314.15   726314.25 726314.30 726314.50 726314.60  
0.35         726628.25 726628.30 726628.50 726628.60  
0.50         726316.25 726316.30 726316.50 726316.60  
1.00     726325.15   726325.25 726325.30 726325.50 726325.60  
3.00         726809.25 726809.30 726809.50 726809.60  
5.00     726934.15   726934.25 726934.30 726934.50    
0.53 mm ID (0.8 mm OD)
0.50 726523.10       726523.25 726523.30      
1.00 726541.10   726541.15   726541.25 726541.30      
2.00 726525.10       726525.25 726525.30 726525.50 726525.60  
5.00 726916.10       726916.25 726916.30 726916.50    
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Columns have fused ends or are sealed with septa, to protect them from atmospheric oxygen.
For checking the column performance the respective test mixture can be obtained separately.
On request, all columns can be supplied on a 5 inch (13 cm) cage for the Agilent GC 6850. To order, please add an E at the end of the REF number (e.g., 726807.30E)
To prolong column life, even at highly contaminated or matrix-containing samples, MN offers the option to add an integrated guard column. All capillary columns are available with a 10 m guard column with respective deactivation. To order, please add V1 at the end of the REF number. Guard column combinations with other lengths, IDs or different deactivation are available on request.