Login
     
  
     
  
     

NucleoSpin® 8/96 RNA

Total RNA from cells and tissue

Features 
Time-saving isolation of total RNA for varying throughput in flexible 8-well strip format and for high throughput in approved 96-well format

• Time-saving parallel isolation of total RNA
• DNase included for efficient removal of genomic DNA
• Processing possible under vacuum or by centrifugation
• Suitable for manual and automated processing
• Innovative MN Wash Plate minimizes risk of cross-contamination
• RNA ready-to-use for any kind of enzymatic reaction

NucleoSpin 8 RNA

NucleoSpin 96 RNA

Technology

Silica-membrane technology

Format

8-well strips

96-well plates

Processing

Manual or automated, vacuum or centrifugation

Sample material

< 107 cultured cells (centrifugation)
< 30 mg tissue (centrifugation)

Fragment size

200 b - 20 kbp

200 b - 20 kbp

Typical yield

< 100 µg

< 100 µg

A260/280

1.90 - 2.10

1.90 - 2.10

Typical RIN (RNA integrity number)

> 9 (cells)
³ 7 (tissue)

> 9 (cells)
³ 7 (tissue)

RNA ratio

28S/18S » 2.1

28S/18S » 2.1

Typical concentration

50 - 200 ng/µl

50 - 200 ng/µl

Elution volume

50 - 130 µl

50 - 130 µl

Preparation time

45 min/6 strips

70 min/plate

Binding capacity

100 µg

100 µg

Applications*

• Manual or automated isolation of total RNA from cultured cells and tissue

* Kits to be used for research purposes only

  
Maximize    

     

Ordering information

Product

Preps

Specification Reference
NucleoSpin 8 RNA

12 x 8

NucleoSpin RNA Binding Strips, MN Wash Plates, MN Square-well Blocks, Racks with Tube Strips, Cap Strips, Elution plates U-bottom, Self-adhering Foil, buffers, RNase-free DNase I 740698

60 x 8

as above 740698.5
NucleoSpin 96 RNA

2 x 96

NucleoSpin RNA Binding Plates, MN Wash Plates, Square-well Blocks, Round-well Block (low), Elution Plates U-bottom, Self-adhering Foil, buffers, RNase-free DNase I 740709.2

4 x 96

as above 740709.4

24 x 96

as above 740709.24
Product accessories

Pack of

Specification Reference
NucleoVac 96 Vacuum Manifold

1

740681
NucleoVac Vacuum Regulator

1

for controlling of vacuum 740641
Starter Set A

1

for use of NucleoSpin 8-well strips on the NucleoVac 96 vacuum manifold 740682
Starter Set C

1

for use of NucleoSpin 8-well strips under centrifugation 740684
NucleoSpin RNA Filter Plate

4

96-well plates for filtration of cell and tissue homogenates, for use under vacuum or centrifugation 740711
NucleoSpin RNA Filter Strips

12

8-well strips for filtration of cell and tissue homogenates, for use under vacuum or centrifugation 740699.12F

60

as above 740699.60F

For ordering click here

  
     
  
   
  